The Base for Success
Viteo Base Ti is a titanium bonding base for single tooth restorations. The special, Soft-edge-Design of the bonding surface is suited to the Ivoclar restoration materials[1-2].
The connection between the titanium bonding base and the implant has been certified and coordinated with various used implant systems[3-4].
The special Soft-edge-Design of the bonding surface, including a special geometry and recessed rotation protection, is suited for CAD and press-ceramic materials from Ivoclar[1-2].
- Rounded design of the bonding surface allows a uniform distribution of force[1-2]
- Adjustable abutment height - from 6mm to 4mm[4, 6]
- Recessed rotation protection – safe positioning and support of the restoration materials[2, 5]
- Increased bond strength due to preconditioned surface[7-9]
Materials
The Viteo Base Ti, with its blasted bonding surface and internal antirotation protection, is suitable for PRESS and CAD/CAM-produced restoration materials[4, 10].
IPS e.max CAD
- Aesthetic, high-strength lithium disilicate glass-ceramic for permanent restorations
- Blocks for CAD/CAM applications
IPS e.max Press
- Ingots for the press procedure
- Special, burn-out Viteo Base Press Sleeves for the press technique
Telio CAD
- Highly cross-linked, clinically proven PMMA blocks* and discs for temporary restorations
* Currently only available for Planmeca systems
[1] Eser A., FEM Simulations of Various Abutments for Straumann Bonel Level Implant, Test Report, Ivoclar Vivadent AG, 2019
[2] Albrecht T., Härdi S., Gnos T., Entwicklung eines virtuellen Teststands für dentale Implantat-Abutments, Study Report, Interstaatliche Hochschule für Technik Buchs, 2014.
[3] Burger G., Kompatibilität zu Implantat Systemen- Passgenauigkeit zu verschiedenen Implantat-Systemen bzw. Schnittstellen zum Implantat gemäss Originalteile, Test Report, Ivoclar Vivadent AG, 2015
[4] Scherrer P., Spirig U., Designvalidierungsbericht, Test Report, Ivoclar Vivadent AG, 2016.
[5] Burger G., Ti Cutter for Viteo Ti Abutments, Test Report, Ivoclar Vivadent AG, 2015.
[6] Burger G., Implantat Base Titan Passgenauigkeit Rotationlock, Test Report, Ivoclar Vivadent AG, 2015.
[7] Brot A., Implant Base Ti Scherhaftung, Test Report, Ivoclar Vivadent AG, 2015.
[8] Burger G., Analyse industrielle und manuelle Oberflächen-Konditionierung, Test Report, Ivoclar Vivadent AG, 2016.
[9] Burger G., Randspaltdichtigkeit IV Viteo @ IPS e.max CAD / Multilink Hybrid Abutment, Test Report, Ivoclar Vivadent AG, 2015.
[10] Burger G., Analyse keramische Press- und CAM-Passgenauigkeit @ DF Implant Base Ti, Test Report, Ivoclar Vivadent AG, 2015.